p:IGI-3 Data Import Considerations

Overview

When importing p:IGI-3 projects we have made a number of assumptions in order to map data from p:IGI-3 columns across into the p:IGI+ property model.


Usage: Import p:IGI-3 data... --> Stage 1 of 2: p:IGI-3 file overview


How to use in practice

Considerations for p:IGI-3 Data Import

When importing data from p:IGI-3 data to p:IGI+, which possess different data models, the proposed mapping of default p:IGI-3 properties which is presented during import has made numerous assumptions. Users will have the opportunity to consider these links, decide if they are fit for purpose and edit them if needed during the import process. 

Here is a list of the p:IGI-3 link assumptions for the users consideration:  

  1. All imported p:IGI-3 project data imports and links using p:IGI-3 property base Units Of Measure (UOM) / ratios. There is no need to change the linking of UOM & Ratios of p:IGI-3 to p:IGI+ properties, all conversions and presentation changes will occur post import.
  2. Data pertaining to a sample location is duplicated, linking to both Sample and Well analysis group properties.  Depending on whether your sample is attached to a well or not can be useful for users to un-assign location data from the relevant analysis group if desired.
  3. Well analysis properties will only be indicated as correctly linked once the Name.Well property is successfully linked. Until then despite a valid link the link will be indicated as erroneous.    
  4. The p:IGI-3 UTM Zone property successfully links to both the respective SRS code.Sample and SRS code.Well analysis group property . The linked SRS code.Well does not however populate the well associated UTM property Local Spatial Reference System Epsg Code.  You can choose an appropriate option post import from the well manager Location tab. The chosen well manager option will then overwrite any imported values.
  5. p:IGI-3 properties LithoStratigraphy Top, LithoStratigraphy Base, Period Top and Period Base link to p:IGI+ properties Top/Base Lstrat(Un).Geol and Top/Base Cstrat(Un).Geol respectively. Full hierarchical Litho and Chronostratigraphic data can be populated in well manager post import.
  6. TOC data from p:IGI-3 is assumed to derive from Leco analysis and assigned accordingly to the .Leco analysis group. Please reassign to a different analysis group if required.
  7. p:IGI-3 property PyC6-15 is linked to a newly defined property C6-14.Py-GC.
  8. Visual Kerogen p:IGI-3 properties %Vit, %Inert and %Diff link to newly defined properties %Vit, %Inert, Diff.VisK-RL with expanded equations. If the raw data is present in the project, user is advised to delete imported value, automatically recalculating the property post import. 
  9. p:IGI+ visual kerogen properties Exin., Vit., Inert. hold different equation definitions for both the .VisK-TL and .VisK-RL analysis groups based on the sub-groups that can be identified using each analytical approach.
  10. Gas data will be imported with the unknown [un] property indicator by default. Other indicators available to the user include mole [mol%], volume [vol%] or mass [mass%] fractions. These can be changed using the bulk change option on the linking screen.
  11. p:IGI-3 property C1-C4 is linked to a newly defined p:IGI-3 property C1-C5%.Gas. Here there is an expansion on the non-hydrocarbon denominator side of the equation. If the raw data is present in the project, user is advised to delete imported value, automatically recalculating the property post import. 
  12. Data pertaining to p:IGI-3 Extract analysis metadata is duplicated linking to both Extract and SARA(calc) analysis group properties.  This is due to the mix of analytical methods present on this p:IGI-3 page.
  13. High resolution molecular data will be imported with the unknown [un] property indicator by default. Other indicators available to the user include heights [h], areas [a] or concentrations [ch] or [ca] - use the bulk change option to move your data to e.g. heights if you know it comes from this.
  14. nC6 – nC11 peak data from p:IGI-3 page Gas Chromatography are assumed to derive from the .Sat-GC analysis group. Please reassign the analysis group if required, but be aware of creating a duplicate with properties already assigned to the .WO-GC analysis group.
  15. nC6 – nC11 peak data from p:IGI-3 page Gas Gasolines are assumed to derive from the .WO-GC analysis group. Please reassign the analysis group if required, but be aware of creating duplicates with properties already assigned to the .Sat-GC analysis group.
  16. IntStd and IS-ppm data on p:IGI-3 pages Gas chromatography, and Gasolines is assigned respectively to IS1, IS2.WO-GC properties in p:IGI+. IS-ppm data is correctly duplicated populating both the [ca] (concentration area) and [ch] (concentration height) indicator groups.
  17. IntStd and IS-ppm data on p:IGI-3 pages Steranes, and Terpanes is assigned respectively to IS1, IS2.Sat-GCMS properties in p:IGI+. IS-ppm data is correctly duplicated populating both the [ca] (concentration area) and [ch] (concentration height) indicator groups.
  18. p:IGI-3 properties 27St217, 28St217, 29St217 are linked to newly defined p:IGI+ properties 27St(217), 28St(217), 29St(217).Sat-GCMS respectively. The equations do not include the property 30St(217).Sat-GCMS.  If the raw data is present in the project, user is advised to delete imported values, automatically recalculating the properties post import.  
  19. p:IGI-3 properties St-Lab, St-Date, St-Quality are linked respectively  to p:IGI+ properties Lab., Date. and Quality.Sat-GCMS. Saturate analysis meta-data from the p:IGI-3 properties: Tt-Lab, Tt-Date, Tt-Quality and Mbiom-Lab, Mbiom-Date, Mbiom QC(1-5) are incorrectly linked to the .Geol analysis group creating duplication errors during import. With assignment to the .Sat-GCMS analysis group already taken, IGI suggest excluding these properties during linking.
  20. Data pertaining to p:IGI-3 Isotopic analysis metadata is duplicated linking to both Isotopes and Gas-Iso analysis group properties.  This is due to the mix of analytical methods present on this p:IGI-3 page.
  21. p:IGI-3 properties GC-Lab, GC-Date, GC-Quality are linked respectively to p:IGI+ properties Lab., Date. and Quality.WO-GC. Whole oil meta-data from p:IGI-3 properties: Gasol-Lab,  Gasol-Date,Gasol-Quality are incorrectly linked to the .Geol analysis group creating duplication errors during import. With assignment to the .WO-GC analysis group already taken, IGI suggest excluding these properties during linking.
  22. IntStd and IS-ppm data on p:IGI-3 pages Aromatics, Mono-Aromatic Steroids and Tri-Aromatic Steroids is assigned respectively to IS1, IS2 and IS3.Arom-GCMS properties in p:IGI+. IS-ppm data is correctly duplicated populating both the [ca] (concentration area) and [ch] (concentration height) indicator groups.
  23. p:IGI-3 properties Arom-Lab, Arom-Date, Arom-Quality are linked respectively to p:IGI+ properties Lab., Date., and Quality.Arom-GCMS. Aromatic analysis meta-data from the p:IGI-3 properties: MAS-Lab, MAS-Date, MAS-Quality and TAS-Lab , TAS-Date , TAS-Quality are incorrectly linked to the .Geol analysis group creating duplication errors during import. With assignment to the .Arom-GCMS analysis group already taken, IGI suggest excluding these properties during linking.
  24. p:IGI-3 property TAS29 links to the first eluting TAS29 optical isomer TAS29S.Arom-GCMS given a lack of descriptive information in p:IGI-3 as to the data origin.
  25. p:IGI-3 properties TAS/MAS and 20+21/tot, are linked to the newly defined p:IGI+ properties TAS/MAS and TAS20+21/tot.Arom-GCMS. If the raw data is present in the project, user is advised to delete imported values, automatically recalculating the properties post import.  
  26. p:IGI-3 properties ST, MAS and TAS are linked to the newly defined p:IGI+ properties St/MAS+TAS, MAS/St+TAS, TAS/St+MAS.WO-GCMS respectively. If the raw data is present in the project, the user is advised to recalculate the property post import into p:IGI+. The WO-GCMS analysis group has been used here as it is the only analysis where all data are present. To view the raw data in the same analysis group MAS and TAS will need to have their Analysis Group changing from Arom-GCMS to WO-GCMS during import linking.
  27. p:IGI-3 properties IRMS Interp-1, IRMS Interp-2, IRMS Interp-3, IRMS Interp-4, IRMS Interp-5 will not be mapped on import as these properties are not included in the p:IGI+ property model. IGI suggest excluding them during linking. If desired create User Properties to which the properties can be matched.
  28. p:IGI+ will attempt to autolink up properties present in p:IGI-3 User Defined Columns. If the software fails to find a suitable link the user can either manual link or create a Project Property if necessary.

 


 

© 2024 Integrated Geochemical Interpretation Ltd. All rights reserved.